跳线
Contacts
Tel:+0086-574-88134786
Fax:+0086-574-88134849
Mob: +86 180 0574 6858
     Products&Services
  • Name:
  •    GJS-PMH08 
  • Spec:
  •    GJS-PMH08 
  • Memo:
  •    GJS-PMH08
  • Class:
  •    GJS-PMH08

IN-LINE TYPE FIBER OPTIC CLOSURES

Description

PREMIER’s in-line fiber splice closures are compliant with IEC 1073-1 and YD/T814.1. The closures are made of tough anti-corrosive Polycarbonate that makes the closures ideal for aerial, cable duct, direct burial and well applications.

Our inline closures include GJS-PMH08. The GJS-PMH08 have 4 cable entry ports. The GJS-PMH08 can accommodate up to 4 24-fiber splice trays.

The closures employ gasket-sealing technology that enables ease of installation and re-entry requiring no special tools. Air valve is also available as an optional accessory for direct burial applications.

 

Features

      Reliable gasket sealing

      Easy installation with no special tool required

      Re-enterable with no re-entry kit needed

      High compressive strength

 

Applications

      Suitable for ribbon and bunchy fibers

      Aerial

      Cable duct

      Direct burial

      Well

 

Specifications

Characteristics

Value/Performance

Type

GJS-PMH08

Basic

 

No. of Cable Port

4

Max. Cable Diameter allowed

22mm

Dimension

400X200X110mm

Weight

3Kg

Operating Temperature

-40 ~ +60°C

Fiber Bend Radius

30mm

Max. No. of Splice Trays

4

Max. Capacity (single fiber splice)*1

96

 

 

Specifications

Characteristics

Value/Performance

Methods and Conditions

 

Mechanical

Air Tightness

No air bubble seen

Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa.

Remains100kPa±5kPa

Measure the internal pressure 24 hours later

Air Tightness after re-installation

No air bubble seen and pressure remains

unchanged

Do re-entry and re-installation 3 times and repeat above Air Tightness Tests.

Axial Pulling

Pressure remains

unchanged

Pulling force: 1000N

Time: 1min

Internal air pressure: 60kPa±5kPa

Compression

Pressure remains

unchanged

Applied pressure: 2000N/100mm

Time: 1min

Internal air pressure: 60kPa±5kPa

Impact

Pressure remains

unchanged

Impact energy: 16N.m

No. of impacts: 3

Internal air pressure: 60±5kPa

Bending

Pressure remains

unchanged

Bending angle±45°(in two opposite directions)

Tension: 150N

No. of bending: 10

Internal air pressure: 60kPa±5kPa

Twisting

Pressure remains

unchanged

Twisting angle: ±90°

Torque: 50N

No. of twisting: 10

Internal air pressure: 60kPa±5kPa

Thermal

Temperature Cycling

Pressure drop ≤5kPa

Cycling range: -40 ~ +60°C

Cycling time: 2hrs at -40°C, then 2hrs at +60°C

No. of cycling: 3

Internal air pressure: 60kPa±5kPa

Electrical

Insulation

Resistance between

metal parts:2.0x105

Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water.

Resistance between

each metal part and

ground:2.0x105

High Voltage

No voltage

break-downs

and sparks

Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside


Structural Drawing

 

Part List:

1 Inlet cable

(10)  Plug

(2)  Cable clamp

(11)  Grounding wire

(3)  Gasket tape

(12)  Stainless steel screw

(4)   Insulation tape

(13)  Seal groove

(5)   Splice tray

(14)  Splice protection sleeve Holder

(6)   Cable tie

(15)  Closure body

(7)   Cable strengthening member connect

(16)  Body frame

(8)   Cable strengthening member

(17)  Gasket

(9)   Outlet cable

(18)  Sealed Area

 

            Copyright © Patch cord.,Ltd. All Rights Reserved